기본 콘텐츠로 건너뛰기

WINDOW ERROR CODES

■ WINDOW ERROR CODES
Constant/value Description
ERROR_SUCCESS / The operation completed successfully.

ERROR_INVALID_FUNCTION / Incorrect function.

ERROR_FILE_NOT_FOUND / The system cannot find the file specified.

ERROR_PATH_NOT_FOUND / The system cannot find the path specified.

ERROR_TOO_MANY_OPEN_FILES / The system cannot open the file.

ERROR_ACCESS_DENIED / Access is denied.

ERROR_INVALID_HANDLE / The handle is invalid.

ERROR_ARENA_TRASHED / The storage control blocks were destroyed.

ERROR_NOT_ENOUGH_MEMORY / Not enough storage is available to process this command.

ERROR_INVALID_BLOCK / The storage control block address is invalid.

ERROR_BAD_ENVIRONMENT / The environment is incorrect.

ERROR_BAD_FORMAT / An attempt was made to load a program with an incorrect format.

ERROR_INVALID_ACCESS / The access code is invalid.

ERROR_INVALID_DATA / The data is invalid.

ERROR_OUTOFMEMORY / Not enough storage is available to complete this operation.

ERROR_INVALID_DRIVE / The system cannot find the drive specified.

ERROR_CURRENT_DIRECTORY / The directory cannot be removed.

ERROR_NOT_SAME_DEVICE / The system cannot move the file to a different disk drive.

ERROR_NO_MORE_FILES /  There are no more files.

ERROR_WRITE_PROTECT / The media is write protected.

ERROR_BAD_UNIT / The system cannot find the device specified.

ERROR_NOT_READY / The device is not ready.

ERROR_BAD_COMMAND / The device does not recognize the command.

ERROR_CRC / Data error (cyclic redundancy check).

ERROR_BAD_LENGTH / The program issued a command but the command length is incorrect.

ERROR_SEEK / The drive cannot locate a specific area or track on the disk.

ERROR_NOT_DOS_DISK / The specified disk or diskette cannot be accessed.

ERROR_SECTOR_NOT_FOUND / The drive cannot find the sector requested.

ERROR_OUT_OF_PAPER / The printer is out of paper.

ERROR_WRITE_FAULT / The system cannot write to the specified device.

ERROR_READ_FAULT / The system cannot read from the specified device.

ERROR_GEN_FAILURE / A device attached to the system is not functioning.

ERROR_SHARING_VIOLATION / The process cannot access the file because it is being used by another process.

ERROR_LOCK_VIOLATION / The process cannot access the file because another process has locked a portion of the file.
 
ERROR_SHARING_BUFFER_EXCEEDED / Too many files opened for sharing.

ERROR_HANDLE_EOF / Reached the end of the file.

ERROR_HANDLE_DISK_FULL / The disk is full.

ERROR_NOT_SUPPORTED / The request is not supported.
 
ERROR_BAD_NETPATH / The network path was not found.

ERROR_NETWORK_BUSY /  The network is busy.

ERROR_DEV_NOT_EXIST / The specified network resource or device is no longer available.

ERROR_TOO_MANY_CMDS / The network BIOS command limit has been reached.

ERROR_ADAP_HDW_ERR / A network adapter hardware error occurred.

ERROR_BAD_NET_RESP / The specified server cannot perform the requested operation.

ERROR_UNEXP_NET_ERR / An unexpected network error occurred.

ERROR_BAD_REM_ADAP / The remote adapter is not compatible.

ERROR_PRINTQ_FULL / The printer queue is full.

ERROR_NO_SPOOL_SPACE/ Space to store the file waiting to be printed is not available on the server.

ERROR_PRINT_CANCELLED / Your file waiting to be printed was deleted.

ERROR_NETNAME_DELETED / The specified network name is no longer available.

ERROR_NETWORK_ACCESS_DENIED / Network access is denied.

ERROR_BAD_DEV_TYPE / The network resource type is not correct.

ERROR_BAD_NET_NAME / The network name cannot be found.

ERROR_TOO_MANY_NAMES / The name limit for the local computer network adapter card was exceeded.

ERROR_TOO_MANY_SESS / The network BIOS session limit was exceeded.

ERROR_SHARING_PAUSED / The remote server has been paused or is in the process of being started.

ERROR_REQ_NOT_ACCEP / No more connections can be made to this remote computer at this time because there are already as many connections as the computer can accept.

ERROR_REDIR_PAUSED / The specified printer or disk device has been paused.

ERROR_FILE_EXISTS/ The file exists.

ERROR_CANNOT_MAKE/ The directory or file cannot be created.

ERROR_OUT_OF_STRUCTURES / Storage to process this request is not available.

ERROR_ALREADY_ASSIGNED / The local device name is already in use.

ERROR_INVALID_PASSWORD/ The specified network password is not correct.

ERROR_INVALID_PARAMETER/ The parameter is incorrect.

ERROR_NET_WRITE_FAULT
88
0x58
 A write fault occurred on the network.

ERROR_NO_PROC_SLOTS
89
0x59
 The system cannot start another process at this time.

ERROR_TOO_MANY_SEMAPHORES
100
0x64
 Cannot create another system semaphore.

ERROR_EXCL_SEM_ALREADY_OWNED
101
0x65
 The exclusive semaphore is owned by another process.

ERROR_SEM_IS_SET
102
0x66
 The semaphore is set and cannot be closed.

ERROR_TOO_MANY_SEM_REQUESTS
103
0x67
 The semaphore cannot be set again.

ERROR_INVALID_AT_INTERRUPT_TIME
104
0x68
 Cannot request exclusive semaphores at interrupt time.

ERROR_SEM_OWNER_DIED
105
0x69
 The previous ownership of this semaphore has ended.

ERROR_SEM_USER_LIMIT
106
0x6A
 Insert the diskette for drive %1.

ERROR_DISK_CHANGE
107
0x6B
 The program stopped because an alternate diskette was not inserted.

ERROR_DRIVE_LOCKED
108
0x6C
 The disk is in use or locked by another process.

ERROR_BROKEN_PIPE
109
0x6D
 The pipe has been ended.

ERROR_OPEN_FAILED
110
0x6E
 The system cannot open the device or file specified.

ERROR_BUFFER_OVERFLOW
111
0x6F
 The file name is too long.

ERROR_DISK_FULL
112
0x70
 There is not enough space on the disk.

ERROR_NO_MORE_SEARCH_HANDLES
113
0x71
 No more internal file identifiers available.

ERROR_INVALID_TARGET_HANDLE
114
0x72
 The target internal file identifier is incorrect.

ERROR_INVALID_CATEGORY
117
0x75
 The IOCTL call made by the application program is not correct.

ERROR_INVALID_VERIFY_SWITCH
118
0x76
 The verify-on-write switch parameter value is not correct.

ERROR_BAD_DRIVER_LEVEL
119
0x77
 The system does not support the command requested.

ERROR_CALL_NOT_IMPLEMENTED
120
0x78
 This function is not supported on this system.

ERROR_SEM_TIMEOUT
121
0x79
 The semaphore timeout period has expired.

ERROR_INSUFFICIENT_BUFFER
122
0x7A
 The data area passed to a system call is too small.

ERROR_INVALID_NAME
123
0x7B
 The filename, directory name, or volume label syntax is incorrect.

ERROR_INVALID_LEVEL
124
0x7C
 The system call level is not correct.

ERROR_NO_VOLUME_LABEL
125
0x7D
 The disk has no volume label.

ERROR_MOD_NOT_FOUND
126
0x7E
 The specified module could not be found.

ERROR_PROC_NOT_FOUND
127
0x7F
 The specified procedure could not be found.

ERROR_WAIT_NO_CHILDREN
128
0x80
 There are no child processes to wait for.

ERROR_CHILD_NOT_COMPLETE
129
0x81
 The %1 application cannot be run in Win32 mode.

ERROR_DIRECT_ACCESS_HANDLE
130
0x82
 Attempt to use a file handle to an open disk partition for an operation other than raw disk I/O.

ERROR_NEGATIVE_SEEK
131
0x83
 An attempt was made to move the file pointer before the beginning of the file.

ERROR_SEEK_ON_DEVICE
132
0x84
 The file pointer cannot be set on the specified device or file.

ERROR_IS_JOIN_TARGET
133
0x85
 A JOIN or SUBST command cannot be used for a drive that contains previously joined drives.

ERROR_IS_JOINED
134
0x86
 An attempt was made to use a JOIN or SUBST command on a drive that has already been joined.

ERROR_IS_SUBSTED
135
0x87
 An attempt was made to use a JOIN or SUBST command on a drive that has already been substituted.

ERROR_NOT_JOINED
136
0x88
 The system tried to delete the JOIN of a drive that is not joined.

ERROR_NOT_SUBSTED
137
0x89
 The system tried to delete the substitution of a drive that is not substituted.

ERROR_JOIN_TO_JOIN
138
0x8A
 The system tried to join a drive to a directory on a joined drive.

ERROR_SUBST_TO_SUBST
139
0x8B
 The system tried to substitute a drive to a directory on a substituted drive.

ERROR_JOIN_TO_SUBST
140
0x8C
 The system tried to join a drive to a directory on a substituted drive.

ERROR_SUBST_TO_JOIN
141
0x8D
 The system tried to SUBST a drive to a directory on a joined drive.

ERROR_BUSY_DRIVE
142
0x8E
 The system cannot perform a JOIN or SUBST at this time.

ERROR_SAME_DRIVE
143
0x8F
 The system cannot join or substitute a drive to or for a directory on the same drive.

ERROR_DIR_NOT_ROOT
144
0x90
 The directory is not a subdirectory of the root directory.

ERROR_DIR_NOT_EMPTY
145
0x91
 The directory is not empty.

ERROR_IS_SUBST_PATH
146
0x92
 The path specified is being used in a substitute.

ERROR_IS_JOIN_PATH
147
0x93
 Not enough resources are available to process this command.

ERROR_PATH_BUSY
148
0x94
 The path specified cannot be used at this time.

ERROR_IS_SUBST_TARGET
149
0x95
 An attempt was made to join or substitute a drive for which a directory on the drive is the target of a previous substitute.

ERROR_SYSTEM_TRACE
150
0x96
 System trace information was not specified in your CONFIG.SYS file, or tracing is disallowed.

ERROR_INVALID_EVENT_COUNT
151
0x97
 The number of specified semaphore events for DosMuxSemWait is not correct.

ERROR_TOO_MANY_MUXWAITERS
152
0x98
 DosMuxSemWait did not execute; too many semaphores are already set.

ERROR_INVALID_LIST_FORMAT
153
0x99
 The DosMuxSemWait list is not correct.

ERROR_LABEL_TOO_LONG
154
0x9A
 The volume label you entered exceeds the label character limit of the target file system.

ERROR_TOO_MANY_TCBS
155
0x9B
 Cannot create another thread.

ERROR_SIGNAL_REFUSED
156
0x9C
 The recipient process has refused the signal.

ERROR_DISCARDED
157
0x9D
 The segment is already discarded and cannot be locked.

ERROR_NOT_LOCKED
158
0x9E
 The segment is already unlocked.

ERROR_BAD_THREADID_ADDR
159
0x9F
 The address for the thread ID is not correct.

ERROR_BAD_ARGUMENTS
160
0xA0
 One or more arguments are not correct.

ERROR_BAD_PATHNAME
161
0xA1
 The specified path is invalid.

ERROR_SIGNAL_PENDING
162
0xA2
 A signal is already pending.

ERROR_MAX_THRDS_REACHED
164
0xA4
 No more threads can be created in the system.

ERROR_LOCK_FAILED
167
0xA7
 Unable to lock a region of a file.

ERROR_BUSY
170
0xAA
 The requested resource is in use.

ERROR_CANCEL_VIOLATION
173
0xAD
 A lock request was not outstanding for the supplied cancel region.

ERROR_ATOMIC_LOCKS_NOT_SUPPORTED
174
0xAE
 The file system does not support atomic changes to the lock type.

ERROR_INVALID_SEGMENT_NUMBER
180
0xB4
 The system detected a segment number that was not correct.

ERROR_INVALID_ORDINAL
182
0xB6
 The operating system cannot run %1.

ERROR_ALREADY_EXISTS
183
0xB7
 Cannot create a file when that file already exists.

ERROR_INVALID_FLAG_NUMBER
186
0xBA
 The flag passed is not correct.

ERROR_SEM_NOT_FOUND
187
0xBB
 The specified system semaphore name was not found.

ERROR_INVALID_STARTING_CODESEG
188
0xBC
 The operating system cannot run %1.

ERROR_INVALID_STACKSEG
189
0xBD
 The operating system cannot run %1.

ERROR_INVALID_MODULETYPE
190
0xBE
 The operating system cannot run %1.

ERROR_INVALID_EXE_SIGNATURE
191
0xBF
 Cannot run %1 in Win32 mode.

ERROR_EXE_MARKED_INVALID
192
0xC0
 The operating system cannot run %1.

ERROR_BAD_EXE_FORMAT
193
0xC1
 %1 is not a valid Win32 application.

ERROR_ITERATED_DATA_EXCEEDS_64k
194
0xC2
 The operating system cannot run %1.

ERROR_INVALID_MINALLOCSIZE
195
0xC3
 The operating system cannot run %1.

ERROR_DYNLINK_FROM_INVALID_RING
196
0xC4
 The operating system cannot run this application program.

ERROR_IOPL_NOT_ENABLED
197
0xC5
 The operating system is not presently configured to run this application.

ERROR_INVALID_SEGDPL
198
0xC6
 The operating system cannot run %1.

ERROR_AUTODATASEG_EXCEEDS_64k
199
0xC7
 The operating system cannot run this application program.

ERROR_RING2SEG_MUST_BE_MOVABLE
200
0xC8
 The code segment cannot be greater than or equal to 64K.

ERROR_RELOC_CHAIN_XEEDS_SEGLIM
201
0xC9
 The operating system cannot run %1.

ERROR_INFLOOP_IN_RELOC_CHAIN
202
0xCA
 The operating system cannot run %1.

ERROR_ENVVAR_NOT_FOUND
203
0xCB
 The system could not find the environment option that was entered.

ERROR_NO_SIGNAL_SENT
205
0xCD
 No process in the command subtree has a signal handler.

ERROR_FILENAME_EXCED_RANGE
206
0xCE
 The filename or extension is too long.

ERROR_RING2_STACK_IN_USE
207
0xCF
 The ring 2 stack is in use.

ERROR_META_EXPANSION_TOO_LONG
208
0xD0
 The global filename characters, * or ?, are entered incorrectly or too many global filename characters are specified.

ERROR_INVALID_SIGNAL_NUMBER
209
0xD1
 The signal being posted is not correct.

ERROR_THREAD_1_INACTIVE
210
0xD2
 The signal handler cannot be set.

ERROR_LOCKED
212
0xD4
 The segment is locked and cannot be reallocated.

ERROR_TOO_MANY_MODULES
214
0xD6
 Too many dynamic-link modules are attached to this program or dynamic-link module.

ERROR_NESTING_NOT_ALLOWED
215
0xD7
 Cannot nest calls to LoadModule.

ERROR_EXE_MACHINE_TYPE_MISMATCH
216
0xD8
 The version of %1 is not compatible with the version you're running. Check your computer's system information to see whether you need a x86 (32-bit) or x64 (64-bit) version of the program, and then contact the software publisher.

ERROR_EXE_CANNOT_MODIFY_SIGNED_BINARY
217
0xD9
 The image file %1 is signed, unable to modify.

ERROR_EXE_CANNOT_MODIFY_STRONG_SIGNED_BINARY
218
0xDA
 The image file %1 is strong signed, unable to modify.

ERROR_FILE_CHECKED_OUT
220
0xDC
 This file is checked out or locked for editing by another user.

ERROR_CHECKOUT_REQUIRED
221
0xDD
 The file must be checked out before saving changes.

ERROR_BAD_FILE_TYPE
222
0xDE
 The file type being saved or retrieved has been blocked.

ERROR_FILE_TOO_LARGE
223
0xDF
 The file size exceeds the limit allowed and cannot be saved.

ERROR_FORMS_AUTH_REQUIRED
224
0xE0
 Access Denied. Before opening files in this location, you must first add the web site to your trusted sites list, browse to the web site, and select the option to login automatically.

ERROR_VIRUS_INFECTED
225
0xE1
 Operation did not complete successfully because the file contains a virus.

ERROR_VIRUS_DELETED
226
0xE2
 This file contains a virus and cannot be opened. Due to the nature of this virus, the file has been removed from this location.

ERROR_PIPE_LOCAL
229
0xE5
 The pipe is local.

ERROR_BAD_PIPE
230
0xE6
 The pipe state is invalid.

ERROR_PIPE_BUSY
231
0xE7
 All pipe instances are busy.

ERROR_NO_DATA
232
0xE8
 The pipe is being closed.

ERROR_PIPE_NOT_CONNECTED
233
0xE9
 No process is on the other end of the pipe.

ERROR_MORE_DATA
234
0xEA
 More data is available.

ERROR_VC_DISCONNECTED
240
0xF0
 The session was canceled.

ERROR_INVALID_EA_NAME
254
0xFE
 The specified extended attribute name was invalid.

ERROR_EA_LIST_INCONSISTENT
255
0xFF
 The extended attributes are inconsistent.

WAIT_TIMEOUT
258
0x102
 The wait operation timed out.

ERROR_NO_MORE_ITEMS
259
0x103
 No more data is available.

ERROR_CANNOT_COPY
266
0x10A
 The copy functions cannot be used.

ERROR_DIRECTORY
267
0x10B
 The directory name is invalid.

ERROR_EAS_DIDNT_FIT
275
0x113
 The extended attributes did not fit in the buffer.

ERROR_EA_FILE_CORRUPT
276
0x114
 The extended attribute file on the mounted file system is corrupt.

ERROR_EA_TABLE_FULL
277
0x115
 The extended attribute table file is full.

ERROR_INVALID_EA_HANDLE
278
0x116
 The specified extended attribute handle is invalid.

ERROR_EAS_NOT_SUPPORTED
282
0x11A
 The mounted file system does not support extended attributes.

ERROR_NOT_OWNER
288
0x120
 Attempt to release mutex not owned by caller.

ERROR_TOO_MANY_POSTS
298
0x12A
 Too many posts were made to a semaphore.

ERROR_PARTIAL_COPY
299
0x12B
 Only part of a ReadProcessMemory or WriteProcessMemory request was completed.

ERROR_OPLOCK_NOT_GRANTED
300
0x12C
 The oplock request is denied.

ERROR_INVALID_OPLOCK_PROTOCOL
301
0x12D
 An invalid oplock acknowledgment was received by the system.

ERROR_DISK_TOO_FRAGMENTED
302
0x12E
 The volume is too fragmented to complete this operation.

ERROR_DELETE_PENDING
303
0x12F
 The file cannot be opened because it is in the process of being deleted.

ERROR_MR_MID_NOT_FOUND
317
0x13D
 The system cannot find message text for message number 0x%1 in the message file for %2.

ERROR_SCOPE_NOT_FOUND
318
0x13E
 The scope specified was not found.

ERROR_FAIL_NOACTION_REBOOT
350
0x15E
 No action was taken as a system reboot is required.

ERROR_FAIL_SHUTDOWN
351
0x15F
 The shutdown operation failed.

ERROR_FAIL_RESTART
352
0x160
 The restart operation failed.

ERROR_MAX_SESSIONS_REACHED
353
0x161
 The maximum number of sessions has been reached.

ERROR_THREAD_MODE_ALREADY_BACKGROUND
400
0x190
 The thread is already in background processing mode.

ERROR_THREAD_MODE_NOT_BACKGROUND
401
0x191
 The thread is not in background processing mode.

ERROR_PROCESS_MODE_ALREADY_BACKGROUND
402
0x192
 The process is already in background processing mode.

ERROR_PROCESS_MODE_NOT_BACKGROUND
403
0x193
 The process is not in background processing mode.

ERROR_INVALID_ADDRESS
487
0x1E7
 Attempt to access invalid address.

ERROR_USER_PROFILE_LOAD
500
0x1F4
 User profile cannot be loaded.

ERROR_ARITHMETIC_OVERFLOW
534
0x216
 Arithmetic result exceeded 32 bits.

ERROR_PIPE_CONNECTED
535
0x217
 There is a process on other end of the pipe.

ERROR_PIPE_LISTENING
536
0x218
 Waiting for a process to open the other end of the pipe.

ERROR_VERIFIER_STOP
537
0x219
 Application verifier has found an error in the current process.

ERROR_ABIOS_ERROR
538
0x21A
 An error occurred in the ABIOS subsystem.

ERROR_WX86_WARNING
539
0x21B
 A warning occurred in the WX86 subsystem.

ERROR_WX86_ERROR
540
0x21C
 An error occurred in the WX86 subsystem.

ERROR_TIMER_NOT_CANCELED
541
0x21D
 An attempt was made to cancel or set a timer that has an associated APC and the subject thread is not the thread that originally set the timer with an associated APC routine.

ERROR_UNWIND
542
0x21E
 Unwind exception code.

ERROR_BAD_STACK
543
0x21F
 An invalid or unaligned stack was encountered during an unwind operation.

ERROR_INVALID_UNWIND_TARGET
544
0x220
 An invalid unwind target was encountered during an unwind operation.

ERROR_INVALID_PORT_ATTRIBUTES
545
0x221
 Invalid Object Attributes specified to NtCreatePort or invalid Port Attributes specified to NtConnectPort

ERROR_PORT_MESSAGE_TOO_LONG
546
0x222
 Length of message passed to NtRequestPort or NtRequestWaitReplyPort was longer than the maximum message allowed by the port.

ERROR_INVALID_QUOTA_LOWER
547
0x223
 An attempt was made to lower a quota limit below the current usage.

ERROR_DEVICE_ALREADY_ATTACHED
548
0x224
 An attempt was made to attach to a device that was already attached to another device.

ERROR_INSTRUCTION_MISALIGNMENT
549
0x225
 An attempt was made to execute an instruction at an unaligned address and the host system does not support unaligned instruction references.

ERROR_PROFILING_NOT_STARTED
550
0x226
 Profiling not started.

ERROR_PROFILING_NOT_STOPPED
551
0x227
 Profiling not stopped.

ERROR_COULD_NOT_INTERPRET
552
0x228
 The passed ACL did not contain the minimum required information.

ERROR_PROFILING_AT_LIMIT
553
0x229
 The number of active profiling objects is at the maximum and no more may be started.

ERROR_CANT_WAIT
554
0x22A
 Used to indicate that an operation cannot continue without blocking for I/O.

ERROR_CANT_TERMINATE_SELF
555
0x22B
 Indicates that a thread attempted to terminate itself by default (called NtTerminateThread with NULL) and it was the last thread in the current process.

ERROR_UNEXPECTED_MM_CREATE_ERR
556
0x22C
 If an MM error is returned which is not defined in the standard FsRtl filter, it is converted to one of the following errors which is guaranteed to be in the filter. In this case information is lost, however, the filter correctly handles the exception.

ERROR_UNEXPECTED_MM_MAP_ERROR
557
0x22D
 If an MM error is returned which is not defined in the standard FsRtl filter, it is converted to one of the following errors which is guaranteed to be in the filter. In this case information is lost, however, the filter correctly handles the exception.

ERROR_UNEXPECTED_MM_EXTEND_ERR
558
0x22E
 If an MM error is returned which is not defined in the standard FsRtl filter, it is converted to one of the following errors which is guaranteed to be in the filter. In this case information is lost, however, the filter correctly handles the exception.

ERROR_BAD_FUNCTION_TABLE
559
0x22F
 A malformed function table was encountered during an unwind operation.

ERROR_NO_GUID_TRANSLATION
560
0x230
 Indicates that an attempt was made to assign protection to a file system file or directory and one of the SIDs in the security descriptor could not be translated into a GUID that could be stored by the file system. This causes the protection attempt to fail, which may cause a file creation attempt to fail.

ERROR_INVALID_LDT_SIZE
561
0x231
 Indicates that an attempt was made to grow an LDT by setting its size, or that the size was not an even number of selectors.

ERROR_INVALID_LDT_OFFSET
563
0x233
 Indicates that the starting value for the LDT information was not an integral multiple of the selector size.

ERROR_INVALID_LDT_DESCRIPTOR
564
0x234
 Indicates that the user supplied an invalid descriptor when trying to set up Ldt descriptors.

ERROR_TOO_MANY_THREADS
565
0x235
 Indicates a process has too many threads to perform the requested action. For example, assignment of a primary token may only be performed when a process has zero or one threads.

ERROR_THREAD_NOT_IN_PROCESS
566
0x236
 An attempt was made to operate on a thread within a specific process, but the thread specified is not in the process specified.

ERROR_PAGEFILE_QUOTA_EXCEEDED
567
0x237
 Page file quota was exceeded.

ERROR_LOGON_SERVER_CONFLICT
568
0x238
 The Netlogon service cannot start because another Netlogon service running in the domain conflicts with the specified role.

ERROR_SYNCHRONIZATION_REQUIRED
569
0x239
 The SAM database on a Windows Server is significantly out of synchronization with the copy on the Domain Controller. A complete synchronization is required.

ERROR_NET_OPEN_FAILED
570
0x23A
 The NtCreateFile API failed. This error should never be returned to an application, it is a place holder for the Windows Lan Manager Redirector to use in its internal error mapping routines.

ERROR_IO_PRIVILEGE_FAILED
571
0x23B
 {Privilege Failed} The I/O permissions for the process could not be changed.

ERROR_CONTROL_C_EXIT
572
0x23C
 {Application Exit by CTRL+C} The application terminated as a result of a CTRL+C.

ERROR_MISSING_SYSTEMFILE
573
0x23D
 {Missing System File} The required system file %hs is bad or missing.

ERROR_UNHANDLED_EXCEPTION
574
0x23E
 {Application Error} The exception %s (0x%08lx) occurred in the application at location 0x%08lx.

ERROR_APP_INIT_FAILURE
575
0x23F
 {Application Error} The application failed to initialize properly (0x%lx). Click OK to terminate the application.

ERROR_PAGEFILE_CREATE_FAILED
576
0x240
 {Unable to Create Paging File} The creation of the paging file %hs failed (%lx). The requested size was %ld.

ERROR_INVALID_IMAGE_HASH
577
0x241
 Windows cannot verify the digital signature for this file. A recent hardware or software change might have installed a file that is signed incorrectly or damaged, or that might be malicious software from an unknown source.

ERROR_NO_PAGEFILE
578
0x242
 {No Paging File Specified} No paging file was specified in the system configuration.

ERROR_ILLEGAL_FLOAT_CONTEXT
579
0x243
 {EXCEPTION} A real-mode application issued a floating-point instruction and floating-point hardware is not present.

ERROR_NO_EVENT_PAIR
580
0x244
 An event pair synchronization operation was performed using the thread specific client/server event pair object, but no event pair object was associated with the thread.

ERROR_DOMAIN_CTRLR_CONFIG_ERROR
581
0x245
 A Windows Server has an incorrect configuration.

ERROR_ILLEGAL_CHARACTER
582
0x246
 An illegal character was encountered. For a multi-byte character set this includes a lead byte without a succeeding trail byte. For the Unicode character set this includes the characters 0xFFFF and 0xFFFE.

ERROR_UNDEFINED_CHARACTER
583
0x247
 The Unicode character is not defined in the Unicode character set installed on the system.

ERROR_FLOPPY_VOLUME
584
0x248
 The paging file cannot be created on a floppy diskette.

ERROR_BIOS_FAILED_TO_CONNECT_INTERRUPT
585
0x249
 The system BIOS failed to connect a system interrupt to the device or bus for which the device is connected.

ERROR_BACKUP_CONTROLLER
586
0x24A
 This operation is only allowed for the Primary Domain Controller of the domain.

ERROR_MUTANT_LIMIT_EXCEEDED
587
0x24B
 An attempt was made to acquire a mutant such that its maximum count would have been exceeded.

ERROR_FS_DRIVER_REQUIRED
588
0x24C
 A volume has been accessed for which a file system driver is required that has not yet been loaded.

ERROR_CANNOT_LOAD_REGISTRY_FILE
589
0x24D
 {Registry File Failure} The registry cannot load the hive (file): %hs or its log or alternate. It is corrupt, absent, or not writable.

ERROR_DEBUG_ATTACH_FAILED
590
0x24E
 {Unexpected Failure in DebugActiveProcess} An unexpected failure occurred while processing a DebugActiveProcess API request. You may choose OK to terminate the process, or Cancel to ignore the error.

ERROR_SYSTEM_PROCESS_TERMINATED
591
0x24F
 {Fatal System Error} The %hs system process terminated unexpectedly with a status of 0x%08x (0x%08x 0x%08x). The system has been shut down.

ERROR_DATA_NOT_ACCEPTED
592
0x250
 {Data Not Accepted} The TDI client could not handle the data received during an indication.

ERROR_VDM_HARD_ERROR
593
0x251
 NTVDM encountered a hard error.

ERROR_DRIVER_CANCEL_TIMEOUT
594
0x252
 {Cancel Timeout} The driver %hs failed to complete a canceled I/O request in the allotted time.

ERROR_REPLY_MESSAGE_MISMATCH
595
0x253
 {Reply Message Mismatch} An attempt was made to reply to an LPC message, but the thread specified by the client ID in the message was not waiting on that message.

ERROR_LOST_WRITEBEHIND_DATA
596
0x254
 {Delayed Write Failed} Windows was unable to save all the data for the file %hs. The data has been lost. This error may be caused by a failure of your computer hardware or network connection. Please try to save this file elsewhere.

ERROR_CLIENT_SERVER_PARAMETERS_INVALID
597
0x255
 The parameter(s) passed to the server in the client/server shared memory window were invalid. Too much data may have been put in the shared memory window.

ERROR_NOT_TINY_STREAM
598
0x256
 The stream is not a tiny stream.

ERROR_STACK_OVERFLOW_READ
599
0x257
 The request must be handled by the stack overflow code.

ERROR_CONVERT_TO_LARGE
600
0x258
 Internal OFS status codes indicating how an allocation operation is handled. Either it is retried after the containing onode is moved or the extent stream is converted to a large stream.

ERROR_FOUND_OUT_OF_SCOPE
601
0x259
 The attempt to find the object found an object matching by ID on the volume but it is out of the scope of the handle used for the operation.

ERROR_ALLOCATE_BUCKET
602
0x25A
 The bucket array must be grown. Retry transaction after doing so.

ERROR_MARSHALL_OVERFLOW
603
0x25B
 The user/kernel marshalling buffer has overflowed.

ERROR_INVALID_VARIANT
604
0x25C
 The supplied variant structure contains invalid data.

ERROR_BAD_COMPRESSION_BUFFER
605
0x25D
 The specified buffer contains ill-formed data.

ERROR_AUDIT_FAILED
606
0x25E
 {Audit Failed} An attempt to generate a security audit failed.

ERROR_TIMER_RESOLUTION_NOT_SET
607
0x25F
 The timer resolution was not previously set by the current process.

ERROR_INSUFFICIENT_LOGON_INFO
608
0x260
 There is insufficient account information to log you on.

ERROR_BAD_DLL_ENTRYPOINT
609
0x261
 {Invalid DLL Entrypoint} The dynamic link library %hs is not written correctly. The stack pointer has been left in an inconsistent state. The entrypoint should be declared as WINAPI or STDCALL. Select YES to fail the DLL load. Select NO to continue execution. Selecting NO may cause the application to operate incorrectly.

ERROR_BAD_SERVICE_ENTRYPOINT
610
0x262
 {Invalid Service Callback Entrypoint} The %hs service is not written correctly. The stack pointer has been left in an inconsistent state. The callback entrypoint should be declared as WINAPI or STDCALL. Selecting OK will cause the service to continue operation. However, the service process may operate incorrectly.

ERROR_IP_ADDRESS_CONFLICT1
611
0x263
 There is an IP address conflict with another system on the network

ERROR_IP_ADDRESS_CONFLICT2
612
0x264
 There is an IP address conflict with another system on the network

ERROR_REGISTRY_QUOTA_LIMIT
613
0x265
 {Low On Registry Space} The system has reached the maximum size allowed for the system part of the registry. Additional storage requests will be ignored.

ERROR_NO_CALLBACK_ACTIVE
614
0x266
 A callback return system service cannot be executed when no callback is active.

ERROR_PWD_TOO_SHORT / The password provided is too short to meet the policy of your user account. Please choose a longer password.

ERROR_PWD_TOO_RECENT
616
0x268
 The policy of your user account does not allow you to change passwords too frequently. This is done to prevent users from changing back to a familiar, but potentially discovered, password. If you feel your password has been compromised then please contact your administrator immediately to have a new one assigned.

ERROR_PWD_HISTORY_CONFLICT
617
0x269
 You have attempted to change your password to one that you have used in the past. The policy of your user account does not allow this. Please select a password that you have not previously used.

ERROR_UNSUPPORTED_COMPRESSION
618
0x26A
 The specified compression format is unsupported.

ERROR_INVALID_HW_PROFILE
619
0x26B
 The specified hardware profile configuration is invalid.

ERROR_INVALID_PLUGPLAY_DEVICE_PATH
620
0x26C
 The specified Plug and Play registry device path is invalid.

ERROR_QUOTA_LIST_INCONSISTENT
621
0x26D
 The specified quota list is internally inconsistent with its descriptor.

ERROR_EVALUATION_EXPIRATION
622
0x26E
 {Windows Evaluation Notification} The evaluation period for this installation of Windows has expired. This system will shutdown in 1 hour. To restore access to this installation of Windows, please upgrade this installation using a licensed distribution of this product.

ERROR_ILLEGAL_DLL_RELOCATION
623
0x26F
 {Illegal System DLL Relocation} The system DLL %hs was relocated in memory. The application will not run properly. The relocation occurred because the DLL %hs occupied an address range reserved for Windows system DLLs. The vendor supplying the DLL should be contacted for a new DLL.

ERROR_DLL_INIT_FAILED_LOGOFF
624
0x270
 {DLL Initialization Failed} The application failed to initialize because the window station is shutting down.

ERROR_VALIDATE_CONTINUE
625
0x271
 The validation process needs to continue on to the next step.

ERROR_NO_MORE_MATCHES
626
0x272
 There are no more matches for the current index enumeration.

ERROR_RANGE_LIST_CONFLICT
627
0x273
 The range could not be added to the range list because of a conflict.

ERROR_SERVER_SID_MISMATCH
628
0x274
 The server process is running under a SID different than that required by client.

ERROR_CANT_ENABLE_DENY_ONLY
629
0x275
 A group marked use for deny only cannot be enabled.

ERROR_FLOAT_MULTIPLE_FAULTS
630
0x276
 {EXCEPTION} Multiple floating point faults.

ERROR_FLOAT_MULTIPLE_TRAPS
631
0x277
 {EXCEPTION} Multiple floating point traps.

ERROR_NOINTERFACE
632
0x278
 The requested interface is not supported.

ERROR_DRIVER_FAILED_SLEEP
633
0x279
 {System Standby Failed} The driver %hs does not support standby mode. Updating this driver may allow the system to go to standby mode.

ERROR_CORRUPT_SYSTEM_FILE
634
0x27A
 The system file %1 has become corrupt and has been replaced.

ERROR_COMMITMENT_MINIMUM
635
0x27B
 {Virtual Memory Minimum Too Low} Your system is low on virtual memory. Windows is increasing the size of your virtual memory paging file. During this process, memory requests for some applications may be denied. For more information, see Help.

ERROR_PNP_RESTART_ENUMERATION
636
0x27C
 A device was removed so enumeration must be restarted.

ERROR_SYSTEM_IMAGE_BAD_SIGNATURE
637
0x27D
 {Fatal System Error} The system image %s is not properly signed. The file has been replaced with the signed file. The system has been shut down.

ERROR_PNP_REBOOT_REQUIRED
638
0x27E
 Device will not start without a reboot.

ERROR_INSUFFICIENT_POWER
639
0x27F
 There is not enough power to complete the requested operation.

ERROR_MULTIPLE_FAULT_VIOLATION
640
0x280
 ERROR_MULTIPLE_FAULT_VIOLATION

ERROR_SYSTEM_SHUTDOWN
641
0x281
 The system is in the process of shutting down.

ERROR_PORT_NOT_SET
642
0x282
 An attempt to remove a processes DebugPort was made, but a port was not already associated with the process.

ERROR_DS_VERSION_CHECK_FAILURE
643
0x283
 This version of Windows is not compatible with the behavior version of directory forest, domain or domain controller.

ERROR_RANGE_NOT_FOUND
644
0x284
 The specified range could not be found in the range list.

ERROR_NOT_SAFE_MODE_DRIVER
646
0x286
 The driver was not loaded because the system is booting into safe mode.

ERROR_FAILED_DRIVER_ENTRY
647
0x287
 The driver was not loaded because it failed it's initialization call.

ERROR_DEVICE_ENUMERATION_ERROR
648
0x288
 The "%hs" encountered an error while applying power or reading the device configuration. This may be caused by a failure of your hardware or by a poor connection.

ERROR_MOUNT_POINT_NOT_RESOLVED
649
0x289
 The create operation failed because the name contained at least one mount point which resolves to a volume to which the specified device object is not attached.

ERROR_INVALID_DEVICE_OBJECT_PARAMETER
650
0x28A
 The device object parameter is either not a valid device object or is not attached to the volume specified by the file name.

ERROR_MCA_OCCURED
651
0x28B
 A Machine Check Error has occurred. Please check the system eventlog for additional information.

ERROR_DRIVER_DATABASE_ERROR
652
0x28C
 There was error [%2] processing the driver database.

ERROR_SYSTEM_HIVE_TOO_LARGE
653
0x28D
 System hive size has exceeded its limit.

ERROR_DRIVER_FAILED_PRIOR_UNLOAD
654
0x28E
 The driver could not be loaded because a previous version of the driver is still in memory.

ERROR_VOLSNAP_PREPARE_HIBERNATE
655
0x28F
 {Volume Shadow Copy Service} Please wait while the Volume Shadow Copy Service prepares volume %hs for hibernation.

ERROR_HIBERNATION_FAILURE
656
0x290
 The system has failed to hibernate (The error code is %hs). Hibernation will be disabled until the system is restarted.

ERROR_FILE_SYSTEM_LIMITATION
665
0x299
 The requested operation could not be completed due to a file system limitation

ERROR_ASSERTION_FAILURE
668
0x29C
 An assertion failure has occurred.

ERROR_ACPI_ERROR
669
0x29D
 An error occurred in the ACPI subsystem.

ERROR_WOW_ASSERTION
670
0x29E
 WOW Assertion Error.

ERROR_PNP_BAD_MPS_TABLE
671
0x29F
 A device is missing in the system BIOS MPS table. This device will not be used. Please contact your system vendor for system BIOS update.

ERROR_PNP_TRANSLATION_FAILED
672
0x2A0
 A translator failed to translate resources.

ERROR_PNP_IRQ_TRANSLATION_FAILED
673
0x2A1
 A IRQ translator failed to translate resources.

ERROR_PNP_INVALID_ID
674
0x2A2
 Driver %2 returned invalid ID for a child device (%3).

ERROR_WAKE_SYSTEM_DEBUGGER
675
0x2A3
 {Kernel Debugger Awakened} the system debugger was awakened by an interrupt.

ERROR_HANDLES_CLOSED
676
0x2A4
 {Handles Closed} Handles to objects have been automatically closed as a result of the requested operation.

ERROR_EXTRANEOUS_INFORMATION
677
0x2A5
 {Too Much Information} The specified access control list (ACL) contained more information than was expected.

ERROR_RXACT_COMMIT_NECESSARY
678
0x2A6
 This warning level status indicates that the transaction state already exists for the registry sub-tree, but that a transaction commit was previously aborted. The commit has NOT been completed, but has not been rolled back either (so it may still be committed if desired).

ERROR_MEDIA_CHECK
679
0x2A7
 {Media Changed} The media may have changed.

ERROR_GUID_SUBSTITUTION_MADE
680
0x2A8
 {GUID Substitution} During the translation of a global identifier (GUID) to a Windows security ID (SID), no administratively-defined GUID prefix was found. A substitute prefix was used, which will not compromise system security. However, this may provide a more restrictive access than intended.

ERROR_STOPPED_ON_SYMLINK
681
0x2A9
 The create operation stopped after reaching a symbolic link

ERROR_LONGJUMP
682
0x2AA
 A long jump has been executed.

ERROR_PLUGPLAY_QUERY_VETOED
683
0x2AB
 The Plug and Play query operation was not successful.

ERROR_UNWIND_CONSOLIDATE
684
0x2AC
 A frame consolidation has been executed.

ERROR_REGISTRY_HIVE_RECOVERED
685
0x2AD
 {Registry Hive Recovered} Registry hive (file): %hs was corrupted and it has been recovered. Some data might have been lost.

ERROR_DLL_MIGHT_BE_INSECURE
686
0x2AE
 The application is attempting to run executable code from the module %hs. This may be insecure. An alternative, %hs, is available. Should the application use the secure module %hs?

ERROR_DLL_MIGHT_BE_INCOMPATIBLE
687
0x2AF
 The application is loading executable code from the module %hs. This is secure, but may be incompatible with previous releases of the operating system. An alternative, %hs, is available. Should the application use the secure module %hs?

ERROR_DBG_EXCEPTION_NOT_HANDLED
688
0x2B0
 Debugger did not handle the exception.

ERROR_DBG_REPLY_LATER
689
0x2B1
 Debugger will reply later.

ERROR_DBG_UNABLE_TO_PROVIDE_HANDLE
690
0x2B2
 Debugger cannot provide handle.

ERROR_DBG_TERMINATE_THREAD
691
0x2B3
 Debugger terminated thread.

ERROR_DBG_TERMINATE_PROCESS
692
0x2B4
 Debugger terminated process.

ERROR_DBG_CONTROL_C
693
0x2B5
 Debugger got control C.

ERROR_DBG_PRINTEXCEPTION_C
694
0x2B6
 Debugger printed exception on control C.

ERROR_DBG_RIPEXCEPTION
695
0x2B7
 Debugger received RIP exception.

ERROR_DBG_CONTROL_BREAK
696
0x2B8
 Debugger received control break.

ERROR_DBG_COMMAND_EXCEPTION
697
0x2B9
 Debugger command communication exception.

ERROR_OBJECT_NAME_EXISTS
698
0x2BA
 {Object Exists} An attempt was made to create an object and the object name already existed.

ERROR_THREAD_WAS_SUSPENDED
699
0x2BB
 {Thread Suspended} A thread termination occurred while the thread was suspended. The thread was resumed, and termination proceeded.

ERROR_IMAGE_NOT_AT_BASE
700
0x2BC
 {Image Relocated} An image file could not be mapped at the address specified in the image file. Local fixups must be performed on this image.

ERROR_RXACT_STATE_CREATED
701
0x2BD
 This informational level status indicates that a specified registry sub-tree transaction state did not yet exist and had to be created.

ERROR_SEGMENT_NOTIFICATION
702
0x2BE
 {Segment Load} A virtual DOS machine (VDM) is loading, unloading, or moving an MS-DOS or Win16 program segment image. An exception is raised so a debugger can load, unload or track symbols and breakpoints within these 16-bit segments.

ERROR_BAD_CURRENT_DIRECTORY
703
0x2BF
 {Invalid Current Directory} The process cannot switch to the startup current directory %hs. Select OK to set current directory to %hs, or select CANCEL to exit.

ERROR_FT_READ_RECOVERY_FROM_BACKUP
704
0x2C0
 {Redundant Read} To satisfy a read request, the NT fault-tolerant file system successfully read the requested data from a redundant copy. This was done because the file system encountered a failure on a member of the fault-tolerant volume, but was unable to reassign the failing area of the device.

ERROR_FT_WRITE_RECOVERY
705
0x2C1
 {Redundant Write} To satisfy a write request, the NT fault-tolerant file system successfully wrote a redundant copy of the information. This was done because the file system encountered a failure on a member of the fault-tolerant volume, but was not able to reassign the failing area of the device.

ERROR_IMAGE_MACHINE_TYPE_MISMATCH
706
0x2C2
 {Machine Type Mismatch} The image file %hs is valid, but is for a machine type other than the current machine. Select OK to continue, or CANCEL to fail the DLL load.

ERROR_RECEIVE_PARTIAL
707
0x2C3
 {Partial Data Received} The network transport returned partial data to its client. The remaining data will be sent later.

ERROR_RECEIVE_EXPEDITED
708
0x2C4
 {Expedited Data Received} The network transport returned data to its client that was marked as expedited by the remote system.

ERROR_RECEIVE_PARTIAL_EXPEDITED
709
0x2C5
 {Partial Expedited Data Received} The network transport returned partial data to its client and this data was marked as expedited by the remote system. The remaining data will be sent later.

ERROR_EVENT_DONE
710
0x2C6
 {TDI Event Done} The TDI indication has completed successfully.

ERROR_EVENT_PENDING
711
0x2C7
 {TDI Event Pending} The TDI indication has entered the pending state.

ERROR_CHECKING_FILE_SYSTEM
712
0x2C8
 Checking file system on %wZ

ERROR_FATAL_APP_EXIT
713
0x2C9
 {Fatal Application Exit} %hs

ERROR_PREDEFINED_HANDLE
714
0x2CA
 The specified registry key is referenced by a predefined handle.

ERROR_WAS_UNLOCKED
715
0x2CB
 {Page Unlocked} The page protection of a locked page was changed to 'No Access' and the page was unlocked from memory and from the process.

ERROR_SERVICE_NOTIFICATION
716
0x2CC
 %hs

ERROR_WAS_LOCKED
717
0x2CD
 {Page Locked} One of the pages to lock was already locked.

ERROR_LOG_HARD_ERROR
718
0x2CE
 Application popup: %1 : %2

ERROR_ALREADY_WIN32
719
0x2CF
 ERROR_ALREADY_WIN32

ERROR_IMAGE_MACHINE_TYPE_MISMATCH_EXE
720
0x2D0
 {Machine Type Mismatch} The image file %hs is valid, but is for a machine type other than the current machine.

ERROR_NO_YIELD_PERFORMED
721
0x2D1
 A yield execution was performed and no thread was available to run.

ERROR_TIMER_RESUME_IGNORED
722
0x2D2
 The resumable flag to a timer API was ignored.

ERROR_ARBITRATION_UNHANDLED
723
0x2D3
 The arbiter has deferred arbitration of these resources to its parent

ERROR_CARDBUS_NOT_SUPPORTED
724
0x2D4
 The inserted CardBus device cannot be started because of a configuration error on "%hs".

ERROR_MP_PROCESSOR_MISMATCH
725
0x2D5
 The CPUs in this multiprocessor system are not all the same revision level. To use all processors the operating system restricts itself to the features of the least capable processor in the system. Should problems occur with this system, contact the CPU manufacturer to see if this mix of processors is supported.

ERROR_HIBERNATED
726
0x2D6
 The system was put into hibernation.

ERROR_RESUME_HIBERNATION
727
0x2D7
 The system was resumed from hibernation.

ERROR_FIRMWARE_UPDATED
728
0x2D8
 Windows has detected that the system firmware (BIOS) was updated [previous firmware date = %2, current firmware date %3].

ERROR_DRIVERS_LEAKING_LOCKED_PAGES
729
0x2D9
 A device driver is leaking locked I/O pages causing system degradation. The system has automatically enabled tracking code in order to try and catch the culprit.

ERROR_WAKE_SYSTEM
730
0x2DA
 The system has awoken

ERROR_WAIT_1
731
0x2DB
 ERROR_WAIT_1

ERROR_WAIT_2
732
0x2DC
 ERROR_WAIT_2

ERROR_WAIT_3
733
0x2DD
 ERROR_WAIT_3

ERROR_WAIT_63
734
0x2DE
 ERROR_WAIT_63

ERROR_ABANDONED_WAIT_0
735
0x2DF
 ERROR_ABANDONED_WAIT_0

ERROR_ABANDONED_WAIT_63
736
0x2E0
 ERROR_ABANDONED_WAIT_63

ERROR_USER_APC
737
0x2E1
 ERROR_USER_APC

ERROR_KERNEL_APC
738
0x2E2
 ERROR_KERNEL_APC

ERROR_ALERTED
739
0x2E3
 ERROR_ALERTED

ERROR_ELEVATION_REQUIRED
740
0x2E4
 The requested operation requires elevation.

ERROR_REPARSE
741
0x2E5
 A reparse should be performed by the Object Manager since the name of the file resulted in a symbolic link.

ERROR_OPLOCK_BREAK_IN_PROGRESS
742
0x2E6
 An open/create operation completed while an oplock break is underway.

ERROR_VOLUME_MOUNTED
743
0x2E7
 A new volume has been mounted by a file system.

ERROR_RXACT_COMMITTED
744
0x2E8
 This success level status indicates that the transaction state already exists for the registry sub-tree, but that a transaction commit was previously aborted. The commit has now been completed.

ERROR_NOTIFY_CLEANUP
745
0x2E9
 This indicates that a notify change request has been completed due to closing the handle which made the notify change request.

ERROR_PRIMARY_TRANSPORT_CONNECT_FAILED
746
0x2EA
 {Connect Failure on Primary Transport} An attempt was made to connect to the remote server %hs on the primary transport, but the connection failed. The computer WAS able to connect on a secondary transport.

ERROR_PAGE_FAULT_TRANSITION
747
0x2EB
 Page fault was a transition fault.

ERROR_PAGE_FAULT_DEMAND_ZERO
748
0x2EC
 Page fault was a demand zero fault.

ERROR_PAGE_FAULT_COPY_ON_WRITE
749
0x2ED
 Page fault was a demand zero fault.

ERROR_PAGE_FAULT_GUARD_PAGE
750
0x2EE
 Page fault was a demand zero fault.

ERROR_PAGE_FAULT_PAGING_FILE
751
0x2EF
 Page fault was satisfied by reading from a secondary storage device.

ERROR_CACHE_PAGE_LOCKED
752
0x2F0
 Cached page was locked during operation.

ERROR_CRASH_DUMP
753
0x2F1
 Crash dump exists in paging file.

ERROR_BUFFER_ALL_ZEROS
754
0x2F2
 Specified buffer contains all zeros.

ERROR_REPARSE_OBJECT
755
0x2F3
 A reparse should be performed by the Object Manager since the name of the file resulted in a symbolic link.

ERROR_RESOURCE_REQUIREMENTS_CHANGED
756
0x2F4
 The device has succeeded a query-stop and its resource requirements have changed.

ERROR_TRANSLATION_COMPLETE
757
0x2F5
 The translator has translated these resources into the global space and no further translations should be performed.

ERROR_NOTHING_TO_TERMINATE
758
0x2F6
 A process being terminated has no threads to terminate.

ERROR_PROCESS_NOT_IN_JOB
759
0x2F7
 The specified process is not part of a job.

ERROR_PROCESS_IN_JOB
760
0x2F8
 The specified process is part of a job.

ERROR_VOLSNAP_HIBERNATE_READY
761
0x2F9
 {Volume Shadow Copy Service} The system is now ready for hibernation.

ERROR_FSFILTER_OP_COMPLETED_SUCCESSFULLY
762
0x2FA
 A file system or file system filter driver has successfully completed an FsFilter operation.

ERROR_INTERRUPT_VECTOR_ALREADY_CONNECTED
763
0x2FB
 The specified interrupt vector was already connected.

ERROR_INTERRUPT_STILL_CONNECTED
764
0x2FC
 The specified interrupt vector is still connected.

ERROR_WAIT_FOR_OPLOCK
765
0x2FD
 An operation is blocked waiting for an oplock.

ERROR_DBG_EXCEPTION_HANDLED
766
0x2FE
 Debugger handled exception

ERROR_DBG_CONTINUE
767
0x2FF
 Debugger continued

ERROR_CALLBACK_POP_STACK
768
0x300
 An exception occurred in a user mode callback and the kernel callback frame should be removed.

ERROR_COMPRESSION_DISABLED
769
0x301
 Compression is disabled for this volume.

ERROR_CANTFETCHBACKWARDS
770
0x302
 The data provider cannot fetch backwards through a result set.

ERROR_CANTSCROLLBACKWARDS
771
0x303
 The data provider cannot scroll backwards through a result set.

ERROR_ROWSNOTRELEASED
772
0x304
 The data provider requires that previously fetched data is released before asking for more data.

ERROR_BAD_ACCESSOR_FLAGS
773
0x305
 The data provider was not able to interpret the flags set for a column binding in an accessor.

ERROR_ERRORS_ENCOUNTERED
774
0x306
 One or more errors occurred while processing the request.

ERROR_NOT_CAPABLE
775
0x307
 The implementation is not capable of performing the request.

ERROR_REQUEST_OUT_OF_SEQUENCE
776
0x308
 The client of a component requested an operation which is not valid given the state of the component instance.

ERROR_VERSION_PARSE_ERROR
777
0x309
 A version number could not be parsed.

ERROR_BADSTARTPOSITION
778
0x30A
 The iterator's start position is invalid.

ERROR_MEMORY_HARDWARE
779
0x30B
 The hardware has reported an uncorrectable memory error.

ERROR_DISK_REPAIR_DISABLED
780
0x30C
 The attempted operation required self healing to be enabled.

ERROR_INSUFFICIENT_RESOURCE_FOR_SPECIFIED_SHARED_SECTION_SIZE
781
0x30D
 The Desktop heap encountered an error while allocating session memory. There is more information in the system event log.

ERROR_SYSTEM_POWERSTATE_TRANSITION
782
0x30E
 The system power state is transitioning from %2 to %3.

ERROR_SYSTEM_POWERSTATE_COMPLEX_TRANSITION
783
0x30F
 The system power state is transitioning from %2 to %3 but could enter %4.

ERROR_MCA_EXCEPTION
784
0x310
 A thread is getting dispatched with MCA EXCEPTION because of MCA.

ERROR_ACCESS_AUDIT_BY_POLICY
785
0x311
 Access to %1 is monitored by policy rule %2.

ERROR_ACCESS_DISABLED_NO_SAFER_UI_BY_POLICY
786
0x312
 Access to %1 has been restricted by your Administrator by policy rule %2.

ERROR_ABANDON_HIBERFILE
787
0x313
 A valid hibernation file has been invalidated and should be abandoned.

ERROR_LOST_WRITEBEHIND_DATA_NETWORK_DISCONNECTED
788
0x314
 {Delayed Write Failed} Windows was unable to save all the data for the file %hs; the data has been lost. This error may be caused by network connectivity issues. Please try to save this file elsewhere.

ERROR_LOST_WRITEBEHIND_DATA_NETWORK_SERVER_ERROR
789
0x315
 {Delayed Write Failed} Windows was unable to save all the data for the file %hs; the data has been lost. This error was returned by the server on which the file exists. Please try to save this file elsewhere.

ERROR_LOST_WRITEBEHIND_DATA_LOCAL_DISK_ERROR
790
0x316
 {Delayed Write Failed} Windows was unable to save all the data for the file %hs; the data has been lost. This error may be caused if the device has been removed or the media is write-protected.

ERROR_BAD_MCFG_TABLE
791
0x317
 The resources required for this device conflict with the MCFG table.

ERROR_EA_ACCESS_DENIED
994
0x3E2
 Access to the extended attribute was denied.

ERROR_OPERATION_ABORTED
995
0x3E3
 The I/O operation has been aborted because of either a thread exit or an application request.

ERROR_IO_INCOMPLETE
996
0x3E4
 Overlapped I/O event is not in a signaled state.

ERROR_IO_PENDING
997
0x3E5
 Overlapped I/O operation is in progress.

ERROR_NOACCESS
998
0x3E6
 Invalid access to memory location.

ERROR_SWAPERROR
999
0x3E7
 Error performing inpage operation.
 

 

댓글

이 블로그의 인기 게시물

80040154 오류로 인해 CLSID가 {xxxx-...}인 구성 요소의 COM 클래스 팩터리를 검색하지 못했습니다.

원문보기 .NET 으로 만든 응용프로그램에서 com 객체를 호출한 경우 Windows7 64bit 에서 제목과 같은 에러가 발생했다. Win32 COM 과 .NET 프로그램간의 호환성 때문에 생긴 문제였다. 원인은 .NET 실행시 JIT 컴파일러에 의해 최적화된 기계어로 변환되기 때문.. Win32 COM은 컴파일시.. Win32 COM에 맞춰 빌드 속성에서 하위버전으로 맞춰 컴파일을 다시하는 방법도 있지만 메인 프로젝트가 .NET이라면 참조되는 모든 프로젝트를 다 바꿔야할 노릇.. 또 다른 방법은 COM+를 이용하여 독립적으로 만드는 것이다. 분리시키는 방법은 아래 주소해서 확인할 수 있다. http://support.microsoft.com/kb/281335 나의 경우는 Win32 COM DLL을 64비트 .NET 프로그램에서 참조하니 COM 객체를 제대로 호출하지 못하였습니다. 그래서 .NET 프로그램의 Target Machine을 x86으로 설정하니 제대로 COM 객체를 호출하였습니다.

[Pyinstaller] 실행 파일 관리자 권한 획득하기

고객사에서 일부 사용자에게서 프로그램 오류가 발생한다며 아래와 같이 에러 캡처를 보내왔습니다. 프로그램에서 로그를 남기기 위해 로그 파일을 생성하는데 권한의 문제로 로그 파일을 생성하지 못해 프로그램 오류가 발생한 것 같습니다. 처음에는 Python 코드에서 관리자 권한을 요청하는 코드를 넣으려고 했는데, 실제로 Stackoverflow를 찾아보면 이런 내용이 나옵니다. 프로그램이 관리자 권한으로 실행되지 않았다면 관리자 권한으로 다시 프로그램을 실행시키는 코드입니다. import os import sys import win32com.shell.shell as shell ASADMIN = 'asadmin' if sys.argv[-1] != ASADMIN: script = os.path.abspath(sys.argv[0]) params = ' '.join([script] + sys.argv[1:] + [ASADMIN]) shell.ShellExecuteEx(lpVerb='runas', lpFile=sys.executable, lpParameters=params) sys.exit(0) 하지만 개인적으로 이런 방식은 마음에 들지 않았고 조금 더 찾아보니 Pyinstaller로 exe 파일을 만들 때 옵션을 설정하여 관리자 권한을 요청하도록 할 수 있다고 합니다. --uac-admin을 옵션에 추가하면 프로그램 실행 시 관리자 권한을 요청할 수 있습니다. pyinstaller.exe --uac-admin sample.py 하지만 안타깝게도 이 방식은 원하는 대로 동작하지 않았습니다. 마지막으로 manifest 파일을 이용하여 시도해보았습니다. spec 파일을 이용하여 pyinstaller로 빌드하면 <실행 파일 이름>.manifest 라는 파일이 생성됩니다. 파일에서 아랫부분을 찾아볼 수 있습니다. <security> <re

초간단 프로그램 락 걸기

프로그램에 락을 걸 일이 생겨났다. 하드웨어 락을 걸면 쉬울텐데 그 정도는 아니고 프로그램의 실행 날짜를 제한 해 달라고 한다. 그래서 파일(license.lic)을 가지고 락을 걸리고 결정을 했다. 요구 사항은 아래와 같다. 1. license.lic 파일이 없으면 프로그램을 실행 할수 없게 한다. 2. 지정한 날짜를 넘어서는 프로그램을 실행 할수 없게 한다. 3. 사용자가 시스템 날짜를 되돌렸을때 인식하여 프로그램을 실행 할수 없게 한다. 음.... 1.번 문제는 사용자가 프로그램을 실행하기 위해서 license.lic 파일을 받아야만 한다. license.lic 파일에는 최근 실행 날짜/종료날짜 이런식으로 적도록 한다.(물론 내용은 암호화 한다.) 최근 실행날짜는 프로그램이 실행때마다 업데이트 하도록 하고 시스템 날짜와 비교하여 시스템 날짜가 최근 실행 날짜보다 이전의 날짜면 시스템 날짜를 되돌렸다고 인식하도록 한다.(3.번 문제 해결) 시스템 날짜와 종료 날짜를 비교하여 시스템 날짜가 종료 날짜를 넘으면 프로그램을 실행 할수 없도록 한다.(2.번 문제 해결)